Journal article 981 views 109 downloads
Groundwater Remediation of Volatile Organic Compounds Using Nanofiltration and Reverse Osmosis Membranes—A Field Study
Membranes, Volume: 11, Issue: 1, Start page: 61
Swansea University Authors: Thomas Ainscough, Darren Oatley-Radcliffe , Andrew Barron
-
PDF | Version of Record
© 2021 by the authors. This article is an open access article distributed under the terms of the Creative Commons Attribution (CC BY) license
Download (72.65MB)
DOI (Published version): 10.3390/membranes11010061
Abstract
Groundwater contamination by chlorinated hydrocarbons represents a particularly difficult separation to achieve and very little is published on the subject. In this paper, we explore the potential for the removal of chlorinated volatile and non-volatile organics from a site in Bedfordshire UK. The c...
Published in: | Membranes |
---|---|
ISSN: | 2077-0375 |
Published: |
MDPI AG
2021
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa56235 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract: |
Groundwater contamination by chlorinated hydrocarbons represents a particularly difficult separation to achieve and very little is published on the subject. In this paper, we explore the potential for the removal of chlorinated volatile and non-volatile organics from a site in Bedfordshire UK. The compounds of interest include trichloroethylene (TCE), tetrachloroethylene (PCE), cis-1,2-dichloroethylene (DCE), 2,2-dichloropropane (DCP) and vinyl chloride (VC). The separations were first tested in the laboratory. Microfiltration membranes were of no use in this separation. Nanofiltration membranes performed well and rejections of 70–93% were observed for synthetic solutions and up to 100% for real groundwater samples. Site trials were limited by space and power availability, which resulted in a maximum operating pressure of only 3 bar. Under these conditions, the nanofiltration membrane removed organic materials, but failed to remove VOCs to any significant extent. Initial results with a reverse osmosis membrane were positive, with 93% removal of the VOCs. However, subsequent samples taken demonstrated little removal. Several hypotheses were presented to explain this behavior and the most likely cause of the issue was fouling leading to adsorption of the VOCs onto the membrane and allowing passage through the membrane matrix. |
---|---|
Keywords: |
groundwater; reclamation; nanofiltration; VOC |
College: |
Faculty of Science and Engineering |
Issue: |
1 |
Start Page: |
61 |