Journal article 294 views 161 downloads
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers
Analytical Chemistry, Volume: 89, Issue: 4, Pages: 2232 - 2241
Swansea University Author: Andreas Ipsen
-
PDF | Version of Record
Distributed under a Creative Commons Attribution (CC-BY) License, which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited.
Download (490.71KB)
DOI (Published version): 10.1021/acs.analchem.6b02446
Abstract
The statistical distribution of mass peak centroids recorded on mass spectrometers employing analog-to-digital converters (ADCs) and electron multipliers is derived from the first principles of the data generation process. The resulting Gaussian model is discussed and is validated with experimental...
Published in: | Analytical Chemistry |
---|---|
Published: |
ACS Publications
2017
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa31939 |
first_indexed |
2017-02-14T19:52:52Z |
---|---|
last_indexed |
2018-02-09T05:19:19Z |
id |
cronfa31939 |
recordtype |
SURis |
fullrecord |
<?xml version="1.0"?><rfc1807><datestamp>2018-01-12T11:05:16.9964049</datestamp><bib-version>v2</bib-version><id>31939</id><entry>2017-02-10</entry><title>Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers</title><swanseaauthors><author><sid>5bc63515666926dd39a5ccf64f6ba865</sid><firstname>Andreas</firstname><surname>Ipsen</surname><name>Andreas Ipsen</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2017-02-10</date><abstract>The statistical distribution of mass peak centroids recorded on mass spectrometers employing analog-to-digital converters (ADCs) and electron multipliers is derived from the first principles of the data generation process. The resulting Gaussian model is discussed and is validated with experimental data and with Monte Carlo simulations.</abstract><type>Journal Article</type><journal>Analytical Chemistry</journal><volume>89</volume><journalNumber>4</journalNumber><paginationStart>2232</paginationStart><paginationEnd>2241</paginationEnd><publisher>ACS Publications</publisher><keywords>mass spectrometry, mass peak centroid, statistical distribution</keywords><publishedDay>21</publishedDay><publishedMonth>2</publishedMonth><publishedYear>2017</publishedYear><publishedDate>2017-02-21</publishedDate><doi>10.1021/acs.analchem.6b02446</doi><url/><notes/><college>COLLEGE NANME</college><CollegeCode>COLLEGE CODE</CollegeCode><institution>Swansea University</institution><degreesponsorsfunders>RCUK, MR/J013994/1</degreesponsorsfunders><apcterm/><lastEdited>2018-01-12T11:05:16.9964049</lastEdited><Created>2017-02-10T22:52:06.4608305</Created><path><level id="1">Faculty of Medicine, Health and Life Sciences</level><level id="2">Swansea University Medical School - Medicine</level></path><authors><author><firstname>Andreas</firstname><surname>Ipsen</surname><order>1</order></author></authors><documents><document><filename>0031939-09062017100908.pdf</filename><originalFilename>acs.analchem.6b02446.pdf</originalFilename><uploaded>2017-06-09T10:09:08.7200000</uploaded><type>Output</type><contentLength>473930</contentLength><contentType>application/pdf</contentType><version>Version of Record</version><cronfaStatus>true</cronfaStatus><embargoDate>2017-06-09T00:00:00.0000000</embargoDate><documentNotes>Distributed under a Creative Commons Attribution (CC-BY) License, which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited.</documentNotes><copyrightCorrect>true</copyrightCorrect><language>eng</language></document></documents><OutputDurs/></rfc1807> |
spelling |
2018-01-12T11:05:16.9964049 v2 31939 2017-02-10 Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers 5bc63515666926dd39a5ccf64f6ba865 Andreas Ipsen Andreas Ipsen true false 2017-02-10 The statistical distribution of mass peak centroids recorded on mass spectrometers employing analog-to-digital converters (ADCs) and electron multipliers is derived from the first principles of the data generation process. The resulting Gaussian model is discussed and is validated with experimental data and with Monte Carlo simulations. Journal Article Analytical Chemistry 89 4 2232 2241 ACS Publications mass spectrometry, mass peak centroid, statistical distribution 21 2 2017 2017-02-21 10.1021/acs.analchem.6b02446 COLLEGE NANME COLLEGE CODE Swansea University RCUK, MR/J013994/1 2018-01-12T11:05:16.9964049 2017-02-10T22:52:06.4608305 Faculty of Medicine, Health and Life Sciences Swansea University Medical School - Medicine Andreas Ipsen 1 0031939-09062017100908.pdf acs.analchem.6b02446.pdf 2017-06-09T10:09:08.7200000 Output 473930 application/pdf Version of Record true 2017-06-09T00:00:00.0000000 Distributed under a Creative Commons Attribution (CC-BY) License, which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited. true eng |
title |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers |
spellingShingle |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers Andreas Ipsen |
title_short |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers |
title_full |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers |
title_fullStr |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers |
title_full_unstemmed |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers |
title_sort |
Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers |
author_id_str_mv |
5bc63515666926dd39a5ccf64f6ba865 |
author_id_fullname_str_mv |
5bc63515666926dd39a5ccf64f6ba865_***_Andreas Ipsen |
author |
Andreas Ipsen |
author2 |
Andreas Ipsen |
format |
Journal article |
container_title |
Analytical Chemistry |
container_volume |
89 |
container_issue |
4 |
container_start_page |
2232 |
publishDate |
2017 |
institution |
Swansea University |
doi_str_mv |
10.1021/acs.analchem.6b02446 |
publisher |
ACS Publications |
college_str |
Faculty of Medicine, Health and Life Sciences |
hierarchytype |
|
hierarchy_top_id |
facultyofmedicinehealthandlifesciences |
hierarchy_top_title |
Faculty of Medicine, Health and Life Sciences |
hierarchy_parent_id |
facultyofmedicinehealthandlifesciences |
hierarchy_parent_title |
Faculty of Medicine, Health and Life Sciences |
department_str |
Swansea University Medical School - Medicine{{{_:::_}}}Faculty of Medicine, Health and Life Sciences{{{_:::_}}}Swansea University Medical School - Medicine |
document_store_str |
1 |
active_str |
0 |
description |
The statistical distribution of mass peak centroids recorded on mass spectrometers employing analog-to-digital converters (ADCs) and electron multipliers is derived from the first principles of the data generation process. The resulting Gaussian model is discussed and is validated with experimental data and with Monte Carlo simulations. |
published_date |
2017-02-21T13:03:22Z |
_version_ |
1822679055885926400 |
score |
11.048518 |