E-Thesis 769 views 230 downloads
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling / Hywel Turner Evans
Swansea University Author: Hywel Turner Evans
DOI (Published version): 10.23889/SUthesis.60070
Abstract
Low energy positron clouds from a buer gas trap have been characterised and compressed by a novel double rotating wall (RW) electric field. A theoretical and experimental study comparing compression due to dipolar single and double RW electric fields is presented, with details of a custom-built func...
Published: |
Swansea
2022
|
---|---|
Institution: | Swansea University |
Degree level: | Doctoral |
Degree name: | Ph.D |
Supervisor: | Isaac, Aled ; Charlton, Michael |
URI: | https://cronfa.swan.ac.uk/Record/cronfa60070 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
first_indexed |
2022-05-24T10:21:18Z |
---|---|
last_indexed |
2022-05-25T03:36:50Z |
id |
cronfa60070 |
recordtype |
RisThesis |
fullrecord |
<?xml version="1.0"?><rfc1807><datestamp>2022-05-24T16:25:18.7920567</datestamp><bib-version>v2</bib-version><id>60070</id><entry>2022-05-24</entry><title>Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling</title><swanseaauthors><author><sid>73cc98a5b8e4122fdfcee5d88208b0b7</sid><ORCID>0000-0001-6745-4187</ORCID><firstname>Hywel Turner</firstname><surname>Evans</surname><name>Hywel Turner Evans</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2022-05-24</date><deptcode>HDAT</deptcode><abstract>Low energy positron clouds from a buer gas trap have been characterised and compressed by a novel double rotating wall (RW) electric field. A theoretical and experimental study comparing compression due to dipolar single and double RW electric fields is presented, with details of a custom-built function generator capable of operating on two sets of four, six, and eight-segment electrodes. The installation of a cylindrical Penning trap with two sets of six-segment RW elec-trodes has allowed the implementation of a double RW, which provides a better approximation to the electric potential in the model for independent charged par-ticle compression. A reduction in particle heating has been observed with the double RW, whilst obtaining at least equivalent compression as the single RW, which may in future allow a reduction in the minimum attainable cloud width.Without the use of RW electric fields, optimisations to positron ejection and recapture techniques led to positron clouds being held in a deep, harmonic poten-tial well for over 100 s, enabling time to study RW electric fields and to perform resistive cooling experiments.</abstract><type>E-Thesis</type><journal/><volume/><journalNumber/><paginationStart/><paginationEnd/><publisher/><placeOfPublication>Swansea</placeOfPublication><isbnPrint/><isbnElectronic/><issnPrint/><issnElectronic/><keywords>Positron, physics, antimatter, Penning trap, rotating wall, trapped charged particle</keywords><publishedDay>18</publishedDay><publishedMonth>5</publishedMonth><publishedYear>2022</publishedYear><publishedDate>2022-05-18</publishedDate><doi>10.23889/SUthesis.60070</doi><url/><notes>ORCiD identifier: https://orcid.org/0000-0001-6745-4187</notes><college>COLLEGE NANME</college><department>Health Data Science</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>HDAT</DepartmentCode><institution>Swansea University</institution><supervisor>Isaac, Aled ; Charlton, Michael</supervisor><degreelevel>Doctoral</degreelevel><degreename>Ph.D</degreename><degreesponsorsfunders>Coleg Cymraeg Cenedlaethol; College of Science Swansea University (50/50 match funded); Grant number: YSG17/04 (Coleg Cymraeg Cenedlaethol), none for College of Science</degreesponsorsfunders><apcterm/><lastEdited>2022-05-24T16:25:18.7920567</lastEdited><Created>2022-05-24T11:15:54.9973677</Created><path><level id="1">Faculty of Science and Engineering</level><level id="2">School of Biosciences, Geography and Physics - Physics</level></path><authors><author><firstname>Hywel Turner</firstname><surname>Evans</surname><orcid>0000-0001-6745-4187</orcid><order>1</order></author></authors><documents><document><filename>60070__24161__f9aa6495d69341ffa13544bdfe6ab55d.pdf</filename><originalFilename>Evans_Hywel_PhD_Thesis_Final_Redacted_Signature.pdf</originalFilename><uploaded>2022-05-24T11:42:17.1620599</uploaded><type>Output</type><contentLength>11112776</contentLength><contentType>application/pdf</contentType><version>E-Thesis – open access</version><cronfaStatus>true</cronfaStatus><documentNotes>Copyright: The author, Hywel T. Evans, 2022.</documentNotes><copyrightCorrect>true</copyrightCorrect><language>eng</language></document></documents><OutputDurs/></rfc1807> |
spelling |
2022-05-24T16:25:18.7920567 v2 60070 2022-05-24 Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling 73cc98a5b8e4122fdfcee5d88208b0b7 0000-0001-6745-4187 Hywel Turner Evans Hywel Turner Evans true false 2022-05-24 HDAT Low energy positron clouds from a buer gas trap have been characterised and compressed by a novel double rotating wall (RW) electric field. A theoretical and experimental study comparing compression due to dipolar single and double RW electric fields is presented, with details of a custom-built function generator capable of operating on two sets of four, six, and eight-segment electrodes. The installation of a cylindrical Penning trap with two sets of six-segment RW elec-trodes has allowed the implementation of a double RW, which provides a better approximation to the electric potential in the model for independent charged par-ticle compression. A reduction in particle heating has been observed with the double RW, whilst obtaining at least equivalent compression as the single RW, which may in future allow a reduction in the minimum attainable cloud width.Without the use of RW electric fields, optimisations to positron ejection and recapture techniques led to positron clouds being held in a deep, harmonic poten-tial well for over 100 s, enabling time to study RW electric fields and to perform resistive cooling experiments. E-Thesis Swansea Positron, physics, antimatter, Penning trap, rotating wall, trapped charged particle 18 5 2022 2022-05-18 10.23889/SUthesis.60070 ORCiD identifier: https://orcid.org/0000-0001-6745-4187 COLLEGE NANME Health Data Science COLLEGE CODE HDAT Swansea University Isaac, Aled ; Charlton, Michael Doctoral Ph.D Coleg Cymraeg Cenedlaethol; College of Science Swansea University (50/50 match funded); Grant number: YSG17/04 (Coleg Cymraeg Cenedlaethol), none for College of Science 2022-05-24T16:25:18.7920567 2022-05-24T11:15:54.9973677 Faculty of Science and Engineering School of Biosciences, Geography and Physics - Physics Hywel Turner Evans 0000-0001-6745-4187 1 60070__24161__f9aa6495d69341ffa13544bdfe6ab55d.pdf Evans_Hywel_PhD_Thesis_Final_Redacted_Signature.pdf 2022-05-24T11:42:17.1620599 Output 11112776 application/pdf E-Thesis – open access true Copyright: The author, Hywel T. Evans, 2022. true eng |
title |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling |
spellingShingle |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling Hywel Turner Evans |
title_short |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling |
title_full |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling |
title_fullStr |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling |
title_full_unstemmed |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling |
title_sort |
Double Rotating Wall Compression of Positron Clouds and Towards Resistive Cooling |
author_id_str_mv |
73cc98a5b8e4122fdfcee5d88208b0b7 |
author_id_fullname_str_mv |
73cc98a5b8e4122fdfcee5d88208b0b7_***_Hywel Turner Evans |
author |
Hywel Turner Evans |
author2 |
Hywel Turner Evans |
format |
E-Thesis |
publishDate |
2022 |
institution |
Swansea University |
doi_str_mv |
10.23889/SUthesis.60070 |
college_str |
Faculty of Science and Engineering |
hierarchytype |
|
hierarchy_top_id |
facultyofscienceandengineering |
hierarchy_top_title |
Faculty of Science and Engineering |
hierarchy_parent_id |
facultyofscienceandengineering |
hierarchy_parent_title |
Faculty of Science and Engineering |
department_str |
School of Biosciences, Geography and Physics - Physics{{{_:::_}}}Faculty of Science and Engineering{{{_:::_}}}School of Biosciences, Geography and Physics - Physics |
document_store_str |
1 |
active_str |
0 |
description |
Low energy positron clouds from a buer gas trap have been characterised and compressed by a novel double rotating wall (RW) electric field. A theoretical and experimental study comparing compression due to dipolar single and double RW electric fields is presented, with details of a custom-built function generator capable of operating on two sets of four, six, and eight-segment electrodes. The installation of a cylindrical Penning trap with two sets of six-segment RW elec-trodes has allowed the implementation of a double RW, which provides a better approximation to the electric potential in the model for independent charged par-ticle compression. A reduction in particle heating has been observed with the double RW, whilst obtaining at least equivalent compression as the single RW, which may in future allow a reduction in the minimum attainable cloud width.Without the use of RW electric fields, optimisations to positron ejection and recapture techniques led to positron clouds being held in a deep, harmonic poten-tial well for over 100 s, enabling time to study RW electric fields and to perform resistive cooling experiments. |
published_date |
2022-05-18T04:17:52Z |
_version_ |
1763754190961639424 |
score |
11.0372095 |