Journal article 735 views 135 downloads
A validated reverse-phase high performance liquid chromatography (RP-HPLC) method for the quantification of Gamma- tocotrienol in tocotrienol rich fractions of crude palm oil
Current Nutrition & Food Science, Volume: 17
Swansea University Author: Andrew Morris
-
PDF | Accepted Manuscript
Download (517.65KB)
DOI (Published version): 10.2174/1573401317666210803155717
Abstract
Background: Palm oil and its constituents have wide applications in food, cosmetics and pharmaceutical industries. The tocotrienol-rich fractions of crude palm oil have drawn greater research interest in recent years due to its potent health benefits. Therefore, reliable and validated analytical met...
Published in: | Current Nutrition & Food Science |
---|---|
ISSN: | 1573-4013 |
Published: |
Bentham Science Publishers Ltd.
2021
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa57832 |
Abstract: |
Background: Palm oil and its constituents have wide applications in food, cosmetics and pharmaceutical industries. The tocotrienol-rich fractions of crude palm oil have drawn greater research interest in recent years due to its potent health benefits. Therefore, reliable and validated analytical methods are essential for the quantification of tocotrienols.Objective: This study aimed to develop a simple and economical RP-HPLC method for the quantification of gamma-tocotrienol in tocotrienol rich fractions of crude palm oil.Methods: An Agilent HPLC system supplied with a Diode Array detector and an auto-injector system was used for the method development, and the wavelength was set 295 nm. A reversed-phase C18 column maintained at 30 °C using a mobile phase composition of methanol: water (95:05) at a flow rate of 1 mL/min was used for the analysis. The developed method was validated according to ICH guidelines.Results and discussion: A symmetrical peak of gamma-tocotrienol was observed at 8.7 minutes with minimal peak tailing (between 0.76 and 0.78), and an acceptable resolution above 2.0. Excellent linearity was evident with R2 values 0.9996 and 0.9991 for intra-day and inter-day respectively. The method demonstrated a high precision (%RSD values ≤ 5.8%) and accuracy (%RE<9.6%). The LOD and LOQ of gamma-tocotrienol were determined as 1.4 μg/mL and 4.2 μg/mL respectively. The system suitability studies indicate that the chromatographic parameters are well within the acceptable limit.Conclusion: In conclusion, the developed RP-HPLC method is rapid, precise, stable and economical for the quantification of gamma-tocotrienol. |
---|---|
Keywords: |
TRF, gamma-tocotrienol, RP-HPLC, validation, ICH, system suitability. |
College: |
Faculty of Medicine, Health and Life Sciences |