No Cover Image

Journal article 529 views

A study of temperature control in different designs of emergency drug transport bags

J. Dingley, N. Thatcher, D. Williams, John Dingley

Anaesthesia, Volume: 74, Pages: 868 - 874

Swansea University Author: John Dingley

Full text not available from this repository: check for access using links below.

Check full text

DOI (Published version): 10.1111/anae.14665

Abstract

We examined whether low melting point phase-change waxes might be used in the design of emergency drugtransport bags to reduce the known temperature extremes their contents can be exposed to. Two custom-made hollow-walled drug containers were placed within a pair of drug transport bags to three day/...

Full description

Published in: Anaesthesia
ISSN: 0003-2409 1365-2044
Published: New Jersey, United States Wiley 2019
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa50532
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: We examined whether low melting point phase-change waxes might be used in the design of emergency drugtransport bags to reduce the known temperature extremes their contents can be exposed to. Two custom-made hollow-walled drug containers were placed within a pair of drug transport bags to three day/nightcycles which included periods of direct radiant sunlight. The wall cavities of one container contained air, whereas those of theother contained a paraffin wax with a melting point of 44–46 °C and a high latent heat of fusion (i.e. until fully melted, itstemperature will not increase further). We collected 25,920 sets of temperature data at six locations within and around both containers. We foundthat 97.8% and 84.7% of ampoule temperatures within the wax and air cavity containers, respectively, werewithin a target range of 15–40 °C over the study duration (Levene statisticW = 4279.1; Levene’s test for equalityof variance, p < 0.001). The temperature of the ampoules in the wax cavity container only exceeded 40 °C for 1.7% of thetime. Even when they did so, their temperature was attenuated to 40.3 °C, despite an ambient air temperatureof > 40 °C for 6.4% of the time (peak 46.9 °C) and a bag surface temperature of > 40 °C for 17.2% of the time(peak 64.4 °C). In contrast, the ampoule temperature within the air cavity container was above 40 °C for 17.1% of thetime (peak 54.1 °C). We suggest that the latent heat of fusion of phase-change materials may be used to improve the design of drugtransport bags to mitigate any temperature changes in the drugs stored within.
Keywords: Drug transport, Drug storage, Emergency Medical Team, Thermal stability.
College: Faculty of Medicine, Health and Life Sciences
Start Page: 868
End Page: 874