Abstract
Timetal 407 (Ti-407) is a novel titanium alloy formulated as a lower strength, more malleable alloy offering a range of cost reduction opportunities compared with Ti-6-4 (Ti-6Al-4V). An investigation of the room temperature, high cycle and low cycle fatigue properties of Ti-407 is presented. The eff...
Published in: | MATEC Web of Conferences |
---|---|
ISSN: | 2261-236X |
Published: |
2018
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa40730 |
first_indexed |
2018-06-18T13:33:30Z |
---|---|
last_indexed |
2018-09-04T18:55:03Z |
id |
cronfa40730 |
recordtype |
SURis |
fullrecord |
<?xml version="1.0"?><rfc1807><datestamp>2018-09-04T14:39:29.2174064</datestamp><bib-version>v2</bib-version><id>40730</id><entry>2018-06-18</entry><title>Fatigue Performance of the Novel Titanium Alloy Timetal 407</title><swanseaauthors><author><sid>3453423659f6bcfddcd0a716c6b0e36a</sid><firstname>Martin</firstname><surname>Bache</surname><name>Martin Bache</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>a5277aa17f0f10a481da9e9751ccaeef</sid><ORCID>0000-0003-4838-9572</ORCID><firstname>Helen</firstname><surname>Davies</surname><name>Helen Davies</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2018-06-18</date><abstract>Timetal 407 (Ti-407) is a novel titanium alloy formulated as a lower strength, more malleable alloy offering a range of cost reduction opportunities compared with Ti-6-4 (Ti-6Al-4V). An investigation of the room temperature, high cycle and low cycle fatigue properties of Ti-407 is presented. The effect of thermo-mechanical processing on microstructure is characterised and the fatigue properties of a microstructure containing 30-40% primary alpha volume fraction are presented and discussed. The Ti-407 results are compared with data generated from Ti-6-4 processed to provide a similar microstructure, to demonstrate both superior HCF endurance strength and ductility of the former.</abstract><type>Journal Article</type><journal>MATEC Web of Conferences</journal><volume>165</volume><paginationStart>04001</paginationStart><publisher/><issnElectronic>2261-236X</issnElectronic><keywords/><publishedDay>31</publishedDay><publishedMonth>12</publishedMonth><publishedYear>2018</publishedYear><publishedDate>2018-12-31</publishedDate><doi>10.1051/matecconf/201816504001</doi><url/><notes/><college>COLLEGE NANME</college><CollegeCode>COLLEGE CODE</CollegeCode><institution>Swansea University</institution><apcterm/><lastEdited>2018-09-04T14:39:29.2174064</lastEdited><Created>2018-06-18T10:00:59.1817807</Created><authors><author><firstname>William</firstname><surname>Davey</surname><order>1</order></author><author><firstname>Martin</firstname><surname>Bache</surname><order>2</order></author><author><firstname>Helen</firstname><surname>Davies</surname><orcid>0000-0003-4838-9572</orcid><order>3</order></author><author><firstname>Matthew</firstname><surname>Thomas</surname><order>4</order></author></authors><documents><document><filename>0040730-18062018100307.pdf</filename><originalFilename>davey2018.pdf</originalFilename><uploaded>2018-06-18T10:03:07.3670000</uploaded><type>Output</type><contentLength>1273495</contentLength><contentType>application/pdf</contentType><version>Version of Record</version><cronfaStatus>true</cronfaStatus><embargoDate>2018-06-18T00:00:00.0000000</embargoDate><copyrightCorrect>true</copyrightCorrect><language>eng</language></document></documents><OutputDurs/></rfc1807> |
spelling |
2018-09-04T14:39:29.2174064 v2 40730 2018-06-18 Fatigue Performance of the Novel Titanium Alloy Timetal 407 3453423659f6bcfddcd0a716c6b0e36a Martin Bache Martin Bache true false a5277aa17f0f10a481da9e9751ccaeef 0000-0003-4838-9572 Helen Davies Helen Davies true false 2018-06-18 Timetal 407 (Ti-407) is a novel titanium alloy formulated as a lower strength, more malleable alloy offering a range of cost reduction opportunities compared with Ti-6-4 (Ti-6Al-4V). An investigation of the room temperature, high cycle and low cycle fatigue properties of Ti-407 is presented. The effect of thermo-mechanical processing on microstructure is characterised and the fatigue properties of a microstructure containing 30-40% primary alpha volume fraction are presented and discussed. The Ti-407 results are compared with data generated from Ti-6-4 processed to provide a similar microstructure, to demonstrate both superior HCF endurance strength and ductility of the former. Journal Article MATEC Web of Conferences 165 04001 2261-236X 31 12 2018 2018-12-31 10.1051/matecconf/201816504001 COLLEGE NANME COLLEGE CODE Swansea University 2018-09-04T14:39:29.2174064 2018-06-18T10:00:59.1817807 William Davey 1 Martin Bache 2 Helen Davies 0000-0003-4838-9572 3 Matthew Thomas 4 0040730-18062018100307.pdf davey2018.pdf 2018-06-18T10:03:07.3670000 Output 1273495 application/pdf Version of Record true 2018-06-18T00:00:00.0000000 true eng |
title |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 |
spellingShingle |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 Martin Bache Helen Davies |
title_short |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 |
title_full |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 |
title_fullStr |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 |
title_full_unstemmed |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 |
title_sort |
Fatigue Performance of the Novel Titanium Alloy Timetal 407 |
author_id_str_mv |
3453423659f6bcfddcd0a716c6b0e36a a5277aa17f0f10a481da9e9751ccaeef |
author_id_fullname_str_mv |
3453423659f6bcfddcd0a716c6b0e36a_***_Martin Bache a5277aa17f0f10a481da9e9751ccaeef_***_Helen Davies |
author |
Martin Bache Helen Davies |
author2 |
William Davey Martin Bache Helen Davies Matthew Thomas |
format |
Journal article |
container_title |
MATEC Web of Conferences |
container_volume |
165 |
container_start_page |
04001 |
publishDate |
2018 |
institution |
Swansea University |
issn |
2261-236X |
doi_str_mv |
10.1051/matecconf/201816504001 |
document_store_str |
1 |
active_str |
0 |
description |
Timetal 407 (Ti-407) is a novel titanium alloy formulated as a lower strength, more malleable alloy offering a range of cost reduction opportunities compared with Ti-6-4 (Ti-6Al-4V). An investigation of the room temperature, high cycle and low cycle fatigue properties of Ti-407 is presented. The effect of thermo-mechanical processing on microstructure is characterised and the fatigue properties of a microstructure containing 30-40% primary alpha volume fraction are presented and discussed. The Ti-407 results are compared with data generated from Ti-6-4 processed to provide a similar microstructure, to demonstrate both superior HCF endurance strength and ductility of the former. |
published_date |
2018-12-31T13:32:57Z |
_version_ |
1821412559582920704 |
score |
11.071985 |