Timetal 407 (Ti-407) is a novel titanium alloy formulated as a lower strength, more malleable alloy offering a range of cost reduction opportunities compared with Ti-6-4 (Ti-6Al-4V). An investigation of the room temperature, high cycle and low cycle fatigue properties of Ti-407 is presented. The eff...
Published in: | MATEC Web of Conferences |
---|---|
ISSN: | 2261-236X |
Published: |
2018
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa40730 |
Abstract: |
Timetal 407 (Ti-407) is a novel titanium alloy formulated as a lower strength, more malleable alloy offering a range of cost reduction opportunities compared with Ti-6-4 (Ti-6Al-4V). An investigation of the room temperature, high cycle and low cycle fatigue properties of Ti-407 is presented. The effect of thermo-mechanical processing on microstructure is characterised and the fatigue properties of a microstructure containing 30-40% primary alpha volume fraction are presented and discussed. The Ti-407 results are compared with data generated from Ti-6-4 processed to provide a similar microstructure, to demonstrate both superior HCF endurance strength and ductility of the former. |
---|---|