No Cover Image

Journal article 561 views 54 downloads

Test-Retest, Inter-Rater and Intra-Rater Reliability for Spatiotemporal Gait Parameters Using SANE (an eaSy gAit aNalysis systEm) as Measuring Instrument

Betsy D. M. Chaparro-Rico Orcid Logo, Daniele Cafolla Orcid Logo

Applied Sciences, Volume: 10, Issue: 17, Start page: 5781

Swansea University Author: Daniele Cafolla Orcid Logo

  • 62500_VoR.pdf

    PDF | Version of Record

    © 2020 by the authors. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license

    Download (1.43MB)

Check full text

DOI (Published version): 10.3390/app10175781

Abstract

Studies have demonstrated the validity of Kinect-based systems to measure spatiotemporal parameters of gait. However, few studies have addressed test-retest, inter-rater and intra-rater reliability for spatiotemporal gait parameters. This study aims to assess test-retest, inter-rater and intra-rater...

Full description

Published in: Applied Sciences
ISSN: 2076-3417
Published: MDPI AG 2020
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa62500
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: Studies have demonstrated the validity of Kinect-based systems to measure spatiotemporal parameters of gait. However, few studies have addressed test-retest, inter-rater and intra-rater reliability for spatiotemporal gait parameters. This study aims to assess test-retest, inter-rater and intra-rater reliability of SANE (eaSy gAit aNalysis system) as a measuring instrument for spatiotemporal gait parameters. SANE comprises a depth sensor and a software that automatically estimates spatiotemporal gait parameters using distances between ankles without the need to manually indicate where each gait cycle begins and ends. Gait analysis was conducted by 2 evaluators for 12 healthy subjects during 4 sessions. The reliability was evaluated using Intraclass Correlation Coefficients (ICC). In addition, the Standard Error of the Measurement (SEM), and Smallest Detectable Change (SDC) was calculated. SANE showed from an acceptable to an excellent test-retest, inter-rater and intra-rater reliability; test-retest reliability ranged from 0.62 to 0.81, inter-rater reliability ranged from 0.70 to 0.95 and intra-rater ranged from 0.74 to 0.92. The subject behavior had a greater effect on the reliability of SANE than the evaluator performance. The reliability values of SANE were comparable with other similar studies. SANE, as a feasible and markerless system, has large potential for assessing spatiotemporal gait parameters.
Keywords: gait analysis; spatiotemporal parameters; depth sensor; Kinect; neurorehabilitation; reliability; validity; test-retest reliability; inter-rater reliability; intra-rater reliability
College: Faculty of Science and Engineering
Funders: This work was funded by a grant from Ministero della Salute (Ricerca Corrente 2020).
Issue: 17
Start Page: 5781