Journal article 792 views 32 downloads
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles
Journal of Ultrasound, Volume: 26
Swansea University Author: Chelsea Starbuck
-
PDF | Accepted Manuscript
Download (714.65KB)
DOI (Published version): 10.1007/s40477-022-00699-8
Abstract
Purpose: Although the function of subjects with chronic ankle instability (CAI) has been examined, structural analysis by ultrasound scanning of the structures surrounding the ankle is limited. Before such structural comparisons between injured and uninjured people can be made it is important to inv...
Published in: | Journal of Ultrasound |
---|---|
ISSN: | 1876-7931 |
Published: |
Springer Science and Business Media LLC
2022
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa60810 |
first_indexed |
2022-08-15T10:08:20Z |
---|---|
last_indexed |
2024-11-14T12:18:01Z |
id |
cronfa60810 |
recordtype |
SURis |
fullrecord |
<?xml version="1.0"?><rfc1807><datestamp>2024-07-17T11:58:41.4095963</datestamp><bib-version>v2</bib-version><id>60810</id><entry>2022-08-15</entry><title>Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles</title><swanseaauthors><author><sid>b12b936789e5be3976b2f2c1c8988d4c</sid><ORCID>0000-0001-6266-2876</ORCID><firstname>Chelsea</firstname><surname>Starbuck</surname><name>Chelsea Starbuck</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2022-08-15</date><deptcode>EAAS</deptcode><abstract>Purpose: Although the function of subjects with chronic ankle instability (CAI) has been examined, structural analysis by ultrasound scanning of the structures surrounding the ankle is limited. Before such structural comparisons between injured and uninjured people can be made it is important to investigate a reliable measurement protocol of structures possibly related to CAI. The aim of this study was to investigate the inter-intra examiner reliability of ultrasonic characteristics of selected structures in healthy subjects. Methods: Eleven healthy participants were assessed by an experienced sonographer and inexperienced certificated examiner. Ultrasound images were collected of the ATFL length and ankle muscles of gastrocnemius medialis (GM), tibialis anterior (TA) and peroneals. Thickness was measured for the muscles, whilst cross-sectional area (CSA) was measured for the peroneals. Inexperienced examiner repeated the measurements a week later. Results: Inter-examiner reliability was excellent for all structures (ICC3,1 = 0.91-0,98). Intra-examiner reliability shows excellent agreement for all structures (ICC3,1=0.92-0.98) except GM (good agreement) (ICC3,1 = 0.82). LoA, relative to structure size, ranged from 1.38% to 6.88% for inter-reliability and from 0.07% to 5.79% for intra-reliability. Conclusion: This study shows a high level of inter-intra examiner reliability in measuring the structures possibly related to CAI. Future research has been planned to investigate the structural analysis in CAI by using applied MSUS protocol.</abstract><type>Journal Article</type><journal>Journal of Ultrasound</journal><volume>26</volume><journalNumber/><paginationStart/><paginationEnd/><publisher>Springer Science and Business Media LLC</publisher><placeOfPublication/><isbnPrint/><isbnElectronic/><issnPrint/><issnElectronic>1876-7931</issnElectronic><keywords>Ultrasound Imaging, Ankle, Muscle Tissue, Ligaments, Cross-Sectional Anatomy</keywords><publishedDay>1</publishedDay><publishedMonth>9</publishedMonth><publishedYear>2022</publishedYear><publishedDate>2022-09-01</publishedDate><doi>10.1007/s40477-022-00699-8</doi><url>http://dx.doi.org/10.1007/s40477-022-00699-8</url><notes/><college>COLLEGE NANME</college><department>Engineering and Applied Sciences School</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>EAAS</DepartmentCode><institution>Swansea University</institution><apcterm/><funders>The researcher Bahar Özgül was financially supported by Scientific and Technological
Research Council of Turkey, Directorate of Science Fellowships and Grant Programs [Program
Code: 2214-A, Reference Number: 53325897-115.02-243381].</funders><projectreference/><lastEdited>2024-07-17T11:58:41.4095963</lastEdited><Created>2022-08-15T11:04:18.3070403</Created><path><level id="1">Faculty of Science and Engineering</level><level id="2"/></path><authors><author><firstname>Bahar</firstname><surname>Özgül</surname><orcid>0000-0001-5821-2725</orcid><order>1</order></author><author><firstname>Chelsea</firstname><surname>Starbuck</surname><orcid>0000-0001-6266-2876</orcid><order>2</order></author><author><firstname>Mine Gülden</firstname><surname>Polat</surname><order>3</order></author><author><firstname>Rawan</firstname><surname>Abdeen</surname><order>4</order></author><author><firstname>Christopher</firstname><surname>Nester</surname><order>5</order></author></authors><documents><document><filename>60810__24914__ae7245228cc74b648b7544ffd50272b7.pdf</filename><originalFilename>60810.pdf</originalFilename><uploaded>2022-08-15T11:08:13.5112973</uploaded><type>Output</type><contentLength>731804</contentLength><contentType>application/pdf</contentType><version>Accepted Manuscript</version><cronfaStatus>true</cronfaStatus><embargoDate>2023-09-01T00:00:00.0000000</embargoDate><copyrightCorrect>true</copyrightCorrect><language>eng</language></document></documents><OutputDurs/></rfc1807> |
spelling |
2024-07-17T11:58:41.4095963 v2 60810 2022-08-15 Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles b12b936789e5be3976b2f2c1c8988d4c 0000-0001-6266-2876 Chelsea Starbuck Chelsea Starbuck true false 2022-08-15 EAAS Purpose: Although the function of subjects with chronic ankle instability (CAI) has been examined, structural analysis by ultrasound scanning of the structures surrounding the ankle is limited. Before such structural comparisons between injured and uninjured people can be made it is important to investigate a reliable measurement protocol of structures possibly related to CAI. The aim of this study was to investigate the inter-intra examiner reliability of ultrasonic characteristics of selected structures in healthy subjects. Methods: Eleven healthy participants were assessed by an experienced sonographer and inexperienced certificated examiner. Ultrasound images were collected of the ATFL length and ankle muscles of gastrocnemius medialis (GM), tibialis anterior (TA) and peroneals. Thickness was measured for the muscles, whilst cross-sectional area (CSA) was measured for the peroneals. Inexperienced examiner repeated the measurements a week later. Results: Inter-examiner reliability was excellent for all structures (ICC3,1 = 0.91-0,98). Intra-examiner reliability shows excellent agreement for all structures (ICC3,1=0.92-0.98) except GM (good agreement) (ICC3,1 = 0.82). LoA, relative to structure size, ranged from 1.38% to 6.88% for inter-reliability and from 0.07% to 5.79% for intra-reliability. Conclusion: This study shows a high level of inter-intra examiner reliability in measuring the structures possibly related to CAI. Future research has been planned to investigate the structural analysis in CAI by using applied MSUS protocol. Journal Article Journal of Ultrasound 26 Springer Science and Business Media LLC 1876-7931 Ultrasound Imaging, Ankle, Muscle Tissue, Ligaments, Cross-Sectional Anatomy 1 9 2022 2022-09-01 10.1007/s40477-022-00699-8 http://dx.doi.org/10.1007/s40477-022-00699-8 COLLEGE NANME Engineering and Applied Sciences School COLLEGE CODE EAAS Swansea University The researcher Bahar Özgül was financially supported by Scientific and Technological Research Council of Turkey, Directorate of Science Fellowships and Grant Programs [Program Code: 2214-A, Reference Number: 53325897-115.02-243381]. 2024-07-17T11:58:41.4095963 2022-08-15T11:04:18.3070403 Faculty of Science and Engineering Bahar Özgül 0000-0001-5821-2725 1 Chelsea Starbuck 0000-0001-6266-2876 2 Mine Gülden Polat 3 Rawan Abdeen 4 Christopher Nester 5 60810__24914__ae7245228cc74b648b7544ffd50272b7.pdf 60810.pdf 2022-08-15T11:08:13.5112973 Output 731804 application/pdf Accepted Manuscript true 2023-09-01T00:00:00.0000000 true eng |
title |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles |
spellingShingle |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles Chelsea Starbuck |
title_short |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles |
title_full |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles |
title_fullStr |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles |
title_full_unstemmed |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles |
title_sort |
Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles |
author_id_str_mv |
b12b936789e5be3976b2f2c1c8988d4c |
author_id_fullname_str_mv |
b12b936789e5be3976b2f2c1c8988d4c_***_Chelsea Starbuck |
author |
Chelsea Starbuck |
author2 |
Bahar Özgül Chelsea Starbuck Mine Gülden Polat Rawan Abdeen Christopher Nester |
format |
Journal article |
container_title |
Journal of Ultrasound |
container_volume |
26 |
publishDate |
2022 |
institution |
Swansea University |
issn |
1876-7931 |
doi_str_mv |
10.1007/s40477-022-00699-8 |
publisher |
Springer Science and Business Media LLC |
college_str |
Faculty of Science and Engineering |
hierarchytype |
|
hierarchy_top_id |
facultyofscienceandengineering |
hierarchy_top_title |
Faculty of Science and Engineering |
hierarchy_parent_id |
facultyofscienceandengineering |
hierarchy_parent_title |
Faculty of Science and Engineering |
url |
http://dx.doi.org/10.1007/s40477-022-00699-8 |
document_store_str |
1 |
active_str |
0 |
description |
Purpose: Although the function of subjects with chronic ankle instability (CAI) has been examined, structural analysis by ultrasound scanning of the structures surrounding the ankle is limited. Before such structural comparisons between injured and uninjured people can be made it is important to investigate a reliable measurement protocol of structures possibly related to CAI. The aim of this study was to investigate the inter-intra examiner reliability of ultrasonic characteristics of selected structures in healthy subjects. Methods: Eleven healthy participants were assessed by an experienced sonographer and inexperienced certificated examiner. Ultrasound images were collected of the ATFL length and ankle muscles of gastrocnemius medialis (GM), tibialis anterior (TA) and peroneals. Thickness was measured for the muscles, whilst cross-sectional area (CSA) was measured for the peroneals. Inexperienced examiner repeated the measurements a week later. Results: Inter-examiner reliability was excellent for all structures (ICC3,1 = 0.91-0,98). Intra-examiner reliability shows excellent agreement for all structures (ICC3,1=0.92-0.98) except GM (good agreement) (ICC3,1 = 0.82). LoA, relative to structure size, ranged from 1.38% to 6.88% for inter-reliability and from 0.07% to 5.79% for intra-reliability. Conclusion: This study shows a high level of inter-intra examiner reliability in measuring the structures possibly related to CAI. Future research has been planned to investigate the structural analysis in CAI by using applied MSUS protocol. |
published_date |
2022-09-01T20:14:12Z |
_version_ |
1821347206692601856 |
score |
11.04748 |