No Cover Image

Journal article 267 views 109 downloads

Biopolymeric Anticorrosion Coatings from Cellulose Nanofibrils and Colloidal Lignin Particles

Arman Dastpak, Philip Ansell, Justin Searle Orcid Logo, Mari Lundström, Benjamin P. Wilson

ACS Applied Materials & Interfaces, Volume: 13, Issue: 34, Pages: 41034 - 41045

Swansea University Authors: Philip Ansell, Justin Searle Orcid Logo

  • 58100.pdf

    PDF | Version of Record

    © 2021 The Authors. Released under the terms of a Creative Commons Attribution license

    Download (9.81MB)

Check full text

DOI (Published version): 10.1021/acsami.1c08274

Abstract

This study presents a process for preparation of cellulose–lignin barrier coatings for hot-dip galvanized (HDG) steel by aqueous electrophoretic deposition. Initially, a solution of softwood kraft lignin and diethylene glycol monobutyl ether was used to prepare an aqueous dispersion of colloidal lig...

Full description

Published in: ACS Applied Materials & Interfaces
ISSN: 1944-8244 1944-8252
Published: American Chemical Society (ACS) 2021
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa58100
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: This study presents a process for preparation of cellulose–lignin barrier coatings for hot-dip galvanized (HDG) steel by aqueous electrophoretic deposition. Initially, a solution of softwood kraft lignin and diethylene glycol monobutyl ether was used to prepare an aqueous dispersion of colloidal lignin particles (CLPs) via solvent exchange. Analysis of the dispersion showed that it comprised submicron particles (D = 146 nm) with spherical morphologies and colloidal stability (ζ-potential = −40 mV). Following successful formation, the CLP dispersion was mixed with a suspension of TEMPO-oxidized cellulose nanofibers (TOCN, 1 and 2 g·L–1) at a fixed volumetric ratio (1:1, TOCN–CLPs), and biopolymers were deposited onto HDG steel surfaces at different potentials (0.5 and 3 V). The effects of these variables on coating formation, dry adhesion, and electrochemical properties (3.5% NaCl) were investigated. The scanning electron microscopy results showed that coalescence of CLPs occurs during the drying of composite coatings, resulting in formation of a barrier layer on HDG steel. The scanning vibrating electrode technique results demonstrated that the TOCN–CLP layers reduced the penetration of the electrolyte (3.5% NaCl) to the metal–coating interface for at least 48 h of immersion, with a more prolonged barrier performance for 3 V-deposited coatings. Additional electrochemical impedance spectroscopy studies showed that all four coatings provided increased levels of charge transfer resistance (Rct)—compared to bare HDG steel—although coatings deposited at a higher potential (3 V) and a higher TOCN concentration provided the maximum charge transfer resistance after 15 days of immersion (13.7 cf. 0.2 kΩ·cm2 for HDG steel). Overall, these results highlight the potential of TOCN–CLP biopolymeric composites as a basis for sustainable corrosion protection coatings.
Keywords: water-borne, electrophoretic deposition, galvanized steel, scanning vibrating electrode technique,electrochemical impedance spectroscopy
College: Faculty of Science and Engineering
Issue: 34
Start Page: 41034
End Page: 41045