Journal article 894 views 93 downloads
An in-silico study of the effect of non-linear skin dynamics on skin-mounted accelerometer inference of skull motion
Biomedical Signal Processing and Control, Volume: 70, Start page: 102986
Swansea University Authors: Elisabeth Williams , Desney Greybe, Hari Arora
-
PDF | Accepted Manuscript
©2021 All rights reserved. All article content, except where otherwise noted, is licensed under a Creative Commons Attribution Non-Commercial No Derivatives License (CC-BY-NC-ND)
Download (1.24MB)
DOI (Published version): 10.1016/j.bspc.2021.102986
Abstract
Accurate and precise analysis of head impact telemetry data is important for development of biomechanical models and methodologies to decrease the risk of traumatic brain injury. Systematic review suggests that much existing data lacks verification. Soft tissue artefact is a common problem that is n...
Published in: | Biomedical Signal Processing and Control |
---|---|
ISSN: | 1746-8094 |
Published: |
Elsevier BV
2021
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa57618 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract: |
Accurate and precise analysis of head impact telemetry data is important for development of biomechanical models and methodologies to decrease the risk of traumatic brain injury. Systematic review suggests that much existing data lacks verification. Soft tissue artefact is a common problem that is not frequently addressed. This paper outlines a method of modelling the coupled, non-linear, skull-skin-sensor system. The model is based on a second order underdamped spring mass damper system that incorporates non-linear values to account for the complex dynamic nature of skin. MATLAB was used to simulate the estimated movement of a sensor mounted to the skin relative to measurements collected via a mouthguard sensor. The non-linear elastic and damping models were developed from descriptions in literature. The model assumed a sensor of 8 g, mounted behind the ear. Results were compared to a typical linear system. In small impacts, the linear and non-linear models provided similar accelerations to the skull. However, in large impacts, the acceleration of the sensor was estimated to be 158% greater than the skull acceleration when modelled non-linearly, while a linear model showed only a 0.7% increase. This implies that for small impacts, the nonlinearity of skin-skull dynamics is not an important characteristic for modelling. However, in large impacts, the non-linearity of the skin-skull dynamic can lead to drastic over-estimates of skull acceleration when using skin mounted accelerometers. |
---|---|
Keywords: |
Soft tissue artefact, Skin modelling, Head impact, Skin-mounted sensor, Accelerometer |
College: |
Faculty of Science and Engineering |
Start Page: |
102986 |