No Cover Image

Journal article 569 views 77 downloads

Characterisation of Microparticle Waste from Dental Resin-Based Composites

Steven Mulligan, Jesus Ojeda Ledo Orcid Logo, Gabriella Kakonyi, Steven F. Thornton, Keyvan Moharamzadeh, Nicolas Martin

Materials, Volume: 14, Issue: 16, Start page: 4440

Swansea University Author: Jesus Ojeda Ledo Orcid Logo

  • 57535.pdf

    PDF | Version of Record

    © 2021 by the authors. This is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license

    Download (2.67MB)

Check full text

DOI (Published version): 10.3390/ma14164440

Abstract

Clinical applications of resin-based composite (RBC) generate environmental pollution in the form of microparticulate waste. Methods: SEM, particle size and specific surface area analysis, FT-IR and potentiometric titrations were used to characterise microparticles arising from grinding commercial a...

Full description

Published in: Materials
ISSN: 1996-1944
Published: MDPI AG 2021
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa57535
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: Clinical applications of resin-based composite (RBC) generate environmental pollution in the form of microparticulate waste. Methods: SEM, particle size and specific surface area analysis, FT-IR and potentiometric titrations were used to characterise microparticles arising from grinding commercial and control RBCs as a function of time, at time of generation and after 12 months ageing in water. The RBCs were tested in two states: (i) direct-placement materials polymerised to simulate routine clinical use and (ii) pre-polymerised CAD/CAM ingots milled using CAD/CAM technology. Results: The maximum specific surface area of the direct-placement commercial RBC was seen after 360 s of agitation and was 1290 m2/kg compared with 1017 m2/kg for the control material. The median diameter of the direct-placement commercial RBC was 6.39 μm at 360 s ag-itation and 9.55 μm for the control material. FTIR analysis confirmed that microparticles were sufficiently unique to be identified after 12 months ageing and consistent alteration of the outermost surfaces of particles was observed. Protonation-deprotonation behaviour and the pH of zero proton charge (pHzpc) ≈ 5–6 indicated that the particles are negatively charged at neutral pH7. Conclusion: The large surface area of RBC microparticles allows elution of constituent monomers with potential environmental impacts. Characterisation of this waste is key to understanding potential mitigation strategies.
Keywords: resin-based composite; pollution; microplastic; microparticle; particles size analysis; potentiometric titration; FTIR
College: Faculty of Science and Engineering
Funders: Shirley Glasstone Hughes Research Grant
Issue: 16
Start Page: 4440