Journal article 992 views 1531 downloads
The effect of diabetic ketoacidosis (DKA) and its treatment on clot microstructure: Are they thrombogenic?
Clinical Hemorheology and Microcirculation, Volume: 77, Issue: 2, Pages: 183 - 194
Swansea University Authors: Janet Whitley, Jeffrey Stephens , Rhodri Williams , Adrian Evans
-
PDF | Accepted Manuscript
Download (348.16KB)
DOI (Published version): 10.3233/ch-200957
Abstract
BACKGROUND:Diabetic ketoacidosis (DKA) is a medical emergency with a high mortality rate and is associated with severe metabolic acidosis and dehydration. DKA patients have an increased risk of arterial and venous thromboembolism, however little is known about this metabolic derangement in the first...
Published in: | Clinical Hemorheology and Microcirculation |
---|---|
ISSN: | 1386-0291 1875-8622 |
Published: |
IOS Press
2021
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa56196 |
Abstract: |
BACKGROUND:Diabetic ketoacidosis (DKA) is a medical emergency with a high mortality rate and is associated with severe metabolic acidosis and dehydration. DKA patients have an increased risk of arterial and venous thromboembolism, however little is known about this metabolic derangement in the first 24 hours of admission and to assess its effect on coagulation. We therefore utilised a novel functional marker of clot microstructure (fractal dimension - df) to assess these changes within the first 24 hours. METHODS:Prospective single centre observational study to demonstrate whether the tendency of blood clot formation differs in DKA patients. RESULTS:15 DKA patients and 15 healthy matched controls were recruited. Mean df in the healthy control group was 1.74±0.03. An elevated df of 1.78±0.07 was observed in patients with DKA on admission. The mean pH on admission was 7.14±0.13 and the lactate was 3.6±2.0. df changed significantly in response to standard treatment and was significantly reduced to 1.68±0.09 (2–6& h) and to 1.66±0.08 at 24& h (p < 0.01 One-way ANOVA). df also correlated significantly with lactate and pH (Pearson correlation coefficient 0.479 and –0.675 respectively, p < 0.05). CONCLUSIONS:DKA patients at presentation have a densely organising less permeable thrombogenic clot microstructure as evidenced by high df. These structural changes are due to a combination of dehydration and a profound metabolic acidosis, which was reversed with treatment. These changes were not mirrored in standard clinical markers of thromboge-nicity. |
---|---|
Keywords: |
Diabetic ketoacidosis (DKA), haemorheology, fractal dimension, gel point |
College: |
Faculty of Medicine, Health and Life Sciences |
Issue: |
2 |
Start Page: |
183 |
End Page: |
194 |