No Cover Image

Conference Paper/Proceeding/Abstract 15842 views 337 downloads

Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters

Ioannis Mexis, Grazia Todeschini

2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)

Swansea University Authors: Ioannis Mexis, Grazia Todeschini

DOI (Published version): 10.1109/isgt-europe47291.2020.9248770

Abstract

A voltage unbalance compensation method usingthree single–phase battery energy storage systems (BESSs) isproposed in this paper. A novel control strategy based on orthogonalsignal generation is presented to regulate active and reactivepower injection from the BESS inverters. A modified version ofthe...

Full description

Published in: 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)
ISBN: 978-1-7281-7101-2 9781728171005
Published: IEEE 2020
URI: https://cronfa.swan.ac.uk/Record/cronfa55680
Tags: Add Tag
No Tags, Be the first to tag this record!
first_indexed 2020-11-17T09:11:11Z
last_indexed 2021-06-03T03:21:31Z
id cronfa55680
recordtype SURis
fullrecord <?xml version="1.0"?><rfc1807><datestamp>2021-06-02T16:56:21.0015239</datestamp><bib-version>v2</bib-version><id>55680</id><entry>2020-11-17</entry><title>Voltage Unbalance Mitigation by Novel Control of BESS Single&#x2013;phase Inverters</title><swanseaauthors><author><sid>2b7b3c49b06ce53fc87af2ac52084987</sid><firstname>Ioannis</firstname><surname>Mexis</surname><name>Ioannis Mexis</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>c4ff9050b31bdec0e560b19bfb3b56d3</sid><firstname>Grazia</firstname><surname>Todeschini</surname><name>Grazia Todeschini</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2020-11-17</date><deptcode>FGSEN</deptcode><abstract>A voltage unbalance compensation method usingthree single&#x2013;phase battery energy storage systems (BESSs) isproposed in this paper. A novel control strategy based on orthogonalsignal generation is presented to regulate active and reactivepower injection from the BESS inverters. A modified version ofthe &#x2019;IEEE 13 node&#x2019; benchmark three&#x2013;phase distribution system isbuilt in MATLAB / Simulink and three case studies are illustratedto verify the effectiveness of the proposed compensation method.</abstract><type>Conference Paper/Proceeding/Abstract</type><journal>2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)</journal><volume/><journalNumber/><paginationStart/><paginationEnd/><publisher>IEEE</publisher><placeOfPublication/><isbnPrint>978-1-7281-7101-2</isbnPrint><isbnElectronic>9781728171005</isbnElectronic><issnPrint/><issnElectronic/><keywords>Reactive power, Software packages, Benchmark testing, Rendering (computer graphics), Inverters, Smart grids, Voltage control.</keywords><publishedDay>26</publishedDay><publishedMonth>10</publishedMonth><publishedYear>2020</publishedYear><publishedDate>2020-10-26</publishedDate><doi>10.1109/isgt-europe47291.2020.9248770</doi><url/><notes>Date of Conference: 26-28 Oct. 2020, The Hague, Netherlands.Citation: I. Mexis and G. Todeschini, "Voltage Unbalance Mitigation by Novel Control of BESS Single&#x2013;phase Inverters," 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe), 2020, pp. 146-150, doi: 10.1109/ISGT-Europe47291.2020.9248770.</notes><college>COLLEGE NANME</college><department>Science and Engineering - Faculty</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>FGSEN</DepartmentCode><institution>Swansea University</institution><apcterm>Not Required</apcterm><lastEdited>2021-06-02T16:56:21.0015239</lastEdited><Created>2020-11-17T09:08:05.2287717</Created><path><level id="1">Faculty of Science and Engineering</level><level id="2">School of Engineering and Applied Sciences - Uncategorised</level></path><authors><author><firstname>Ioannis</firstname><surname>Mexis</surname><order>1</order></author><author><firstname>Grazia</firstname><surname>Todeschini</surname><order>2</order></author></authors><documents><document><filename>55680__18677__50743ea19b3f4a7daf09519718df0835.pdf</filename><originalFilename>Mexis_Todeschini_unbalance_BESSs.pdf</originalFilename><uploaded>2020-11-17T09:10:50.9591274</uploaded><type>Output</type><contentLength>1789280</contentLength><contentType>application/pdf</contentType><version>Accepted Manuscript</version><cronfaStatus>true</cronfaStatus><copyrightCorrect>false</copyrightCorrect></document></documents><OutputDurs/></rfc1807>
spelling 2021-06-02T16:56:21.0015239 v2 55680 2020-11-17 Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters 2b7b3c49b06ce53fc87af2ac52084987 Ioannis Mexis Ioannis Mexis true false c4ff9050b31bdec0e560b19bfb3b56d3 Grazia Todeschini Grazia Todeschini true false 2020-11-17 FGSEN A voltage unbalance compensation method usingthree single–phase battery energy storage systems (BESSs) isproposed in this paper. A novel control strategy based on orthogonalsignal generation is presented to regulate active and reactivepower injection from the BESS inverters. A modified version ofthe ’IEEE 13 node’ benchmark three–phase distribution system isbuilt in MATLAB / Simulink and three case studies are illustratedto verify the effectiveness of the proposed compensation method. Conference Paper/Proceeding/Abstract 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe) IEEE 978-1-7281-7101-2 9781728171005 Reactive power, Software packages, Benchmark testing, Rendering (computer graphics), Inverters, Smart grids, Voltage control. 26 10 2020 2020-10-26 10.1109/isgt-europe47291.2020.9248770 Date of Conference: 26-28 Oct. 2020, The Hague, Netherlands.Citation: I. Mexis and G. Todeschini, "Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters," 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe), 2020, pp. 146-150, doi: 10.1109/ISGT-Europe47291.2020.9248770. COLLEGE NANME Science and Engineering - Faculty COLLEGE CODE FGSEN Swansea University Not Required 2021-06-02T16:56:21.0015239 2020-11-17T09:08:05.2287717 Faculty of Science and Engineering School of Engineering and Applied Sciences - Uncategorised Ioannis Mexis 1 Grazia Todeschini 2 55680__18677__50743ea19b3f4a7daf09519718df0835.pdf Mexis_Todeschini_unbalance_BESSs.pdf 2020-11-17T09:10:50.9591274 Output 1789280 application/pdf Accepted Manuscript true false
title Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
spellingShingle Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
Ioannis Mexis
Grazia Todeschini
title_short Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
title_full Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
title_fullStr Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
title_full_unstemmed Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
title_sort Voltage Unbalance Mitigation by Novel Control of BESS Single–phase Inverters
author_id_str_mv 2b7b3c49b06ce53fc87af2ac52084987
c4ff9050b31bdec0e560b19bfb3b56d3
author_id_fullname_str_mv 2b7b3c49b06ce53fc87af2ac52084987_***_Ioannis Mexis
c4ff9050b31bdec0e560b19bfb3b56d3_***_Grazia Todeschini
author Ioannis Mexis
Grazia Todeschini
author2 Ioannis Mexis
Grazia Todeschini
format Conference Paper/Proceeding/Abstract
container_title 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)
publishDate 2020
institution Swansea University
isbn 978-1-7281-7101-2
9781728171005
doi_str_mv 10.1109/isgt-europe47291.2020.9248770
publisher IEEE
college_str Faculty of Science and Engineering
hierarchytype
hierarchy_top_id facultyofscienceandengineering
hierarchy_top_title Faculty of Science and Engineering
hierarchy_parent_id facultyofscienceandengineering
hierarchy_parent_title Faculty of Science and Engineering
department_str School of Engineering and Applied Sciences - Uncategorised{{{_:::_}}}Faculty of Science and Engineering{{{_:::_}}}School of Engineering and Applied Sciences - Uncategorised
document_store_str 1
active_str 0
description A voltage unbalance compensation method usingthree single–phase battery energy storage systems (BESSs) isproposed in this paper. A novel control strategy based on orthogonalsignal generation is presented to regulate active and reactivepower injection from the BESS inverters. A modified version ofthe ’IEEE 13 node’ benchmark three–phase distribution system isbuilt in MATLAB / Simulink and three case studies are illustratedto verify the effectiveness of the proposed compensation method.
published_date 2020-10-26T04:10:05Z
_version_ 1763753701272453120
score 11.013148