Abstract
Sampling rate (Hz) of ActiGraph accelerometers may affect processing of acceleration to activity counts when using a hip-worn monitor, but research is needed to quantify if sampling rate affects actual acceleration (mg's), when using wrist-worn accelerometers and during non-locomotive activitie...
Published in: | Physiological Measurement |
---|---|
ISSN: | 1361-6579 |
Published: |
2019
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa52104 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract: |
Sampling rate (Hz) of ActiGraph accelerometers may affect processing of acceleration to activity counts when using a hip-worn monitor, but research is needed to quantify if sampling rate affects actual acceleration (mg's), when using wrist-worn accelerometers and during non-locomotive activities. Objective: To assess the effect of ActiGraph sampling rate on total counts/15-sec and mean acceleration and to compare differences due to sampling rate between accelerometer wear locations and across different types of activities. Approach: Children (n=29) wore a hip- and wrist-worn accelerometer (sampled at 100 Hz, downsampled in MATLAB to 30 Hz) during rest/transition periods, active video games, and a treadmill test to volitional exhaustion. Mean acceleration and counts/15-sec were computed for each axis and as vector magnitude. Main Results: There were mostly no significant differences in mean acceleration. However, 100 Hz data resulted in significantly more total counts/15-sec (mean bias 4-43 counts/15-sec across axes) for both the hip- and wrist-worn monitor when compared to 30 Hz data. Absolute differences increased with activity intensity (hip: r=0.46-0.63; wrist: r=0.26-0.55) and were greater for hip- versus wrist-worn monitors. Percent agreement between 100 and 30 Hz data was high (97.4-99.7%) when cut-points or machine learning algorithms were used to classify activity intensity. Significance: Our findings support that sampling rate affects the generation of counts but adds that differences increase with intensity and when using hip-worn monitors. We recommend researchers be consistent and vigilantly report the sampling rate used, but note that classifying data into activity intensities resulted in agreement despite differences in sampling rate. |
---|---|
College: |
Faculty of Science and Engineering |
Issue: |
9 |
Start Page: |
095008 |