Journal article 975 views 495 downloads
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface
Artificial Organs
Swansea University Authors: Karl Hawkins , Cathy Thornton
-
PDF | Accepted Manuscript
Download (5.61MB)
DOI (Published version): 10.1111/aor.13409
Abstract
Medical devices, such as ventricular assist devices (VADs), introduce both foreign materials and artificial shear stress to the circulatory system. The effects these have on leukocytes and the immune response are not well understood. Understanding how these two elements combine to affect leukocytes...
Published in: | Artificial Organs |
---|---|
ISSN: | 0160-564X 1525-1594 |
Published: |
2018
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa49111 |
first_indexed |
2019-03-05T14:02:12Z |
---|---|
last_indexed |
2019-03-26T12:22:49Z |
id |
cronfa49111 |
recordtype |
SURis |
fullrecord |
<?xml version="1.0"?><rfc1807><datestamp>2019-03-25T12:47:54.3133285</datestamp><bib-version>v2</bib-version><id>49111</id><entry>2019-03-05</entry><title>Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface</title><swanseaauthors><author><sid>77c39404a9a98c6e2283d84815cba053</sid><ORCID>0000-0003-0174-4151</ORCID><firstname>Karl</firstname><surname>Hawkins</surname><name>Karl Hawkins</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>c71a7a4be7361094d046d312202bce0c</sid><ORCID>0000-0002-5153-573X</ORCID><firstname>Cathy</firstname><surname>Thornton</surname><name>Cathy Thornton</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2019-03-05</date><deptcode>MEDS</deptcode><abstract>Medical devices, such as ventricular assist devices (VADs), introduce both foreign materials and artificial shear stress to the circulatory system. The effects these have on leukocytes and the immune response are not well understood. Understanding how these two elements combine to affect leukocytes may reveal why some patients are susceptible to recurrent device-related infections and provide insight into the development of pump thrombosis. Biomaterials - DLC: diamond-like carbon coated stainless steel; Sap: single-crystal sapphire; and Ti: titanium alloy (Ti6Al4V) were attached to the parallel plates of a rheometer. Whole human blood was left between the two discs for 5 min at +37°C with or without the application of shear stress (0s-1 or 1000s-1). Blood was removed and used for: complete blood cell counts; flow cytometry (leukocyte activation; cell death; microparticle generation; phagocytic ability; and reactive oxygen species (ROS) production); and the production of pro-inflammatory cytokines. L-selectin expression on monocytes was decreased when blood was exposed to the biomaterials both with and without shear. Applying shear stress to blood on a Sap and Ti surface led to activation of neutrophils shown as decreased L-selectin expression. Sap and Ti blunted the LPS-stimulated macrophage migration inhibitory factor (MIF) production, most notably when sheared on Ti.The biomaterials used here have been shown to activate leukocytes in a static environment. The introduction of shear appears to exacerbate this activation. Interestingly, a widely accepted biocompatible material (Ti) utilised in many different types of devices, has the capacity for immune cell activation and inhibition of MIF secretion when combined with shear stress. These findings contribute to our understanding of the contribution of biomaterials and shear stress to recurrent infections and vulnerability to sepsis in some VAD patients as well as pump thrombosis.</abstract><type>Journal Article</type><journal>Artificial Organs</journal><publisher/><issnPrint>0160-564X</issnPrint><issnElectronic>1525-1594</issnElectronic><keywords>Biomaterials, Shear Stress, Human blood, Leukocytes, Flow Cytometry</keywords><publishedDay>8</publishedDay><publishedMonth>1</publishedMonth><publishedYear>2018</publishedYear><publishedDate>2018-01-08</publishedDate><doi>10.1111/aor.13409</doi><url/><notes/><college>COLLEGE NANME</college><department>Medical School</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>MEDS</DepartmentCode><institution>Swansea University</institution><apcterm/><lastEdited>2019-03-25T12:47:54.3133285</lastEdited><Created>2019-03-05T08:39:32.9438049</Created><path><level id="1">Faculty of Medicine, Health and Life Sciences</level><level id="2">Swansea University Medical School - Medicine</level></path><authors><author><firstname>Gemma</firstname><surname>Radley</surname><order>1</order></author><author><firstname>Ina Laura</firstname><surname>Pieper</surname><order>2</order></author><author><firstname>Bethan R.</firstname><surname>Thomas</surname><order>3</order></author><author><firstname>Karl</firstname><surname>Hawkins</surname><orcid>0000-0003-0174-4151</orcid><order>4</order></author><author><firstname>Cathy</firstname><surname>Thornton</surname><orcid>0000-0002-5153-573X</orcid><order>5</order></author></authors><documents><document><filename>0049111-05032019084007.pdf</filename><originalFilename>20180814_Radley_Cronfa.pdf</originalFilename><uploaded>2019-03-05T08:40:07.4800000</uploaded><type>Output</type><contentLength>5850626</contentLength><contentType>application/pdf</contentType><version>Accepted Manuscript</version><cronfaStatus>true</cronfaStatus><embargoDate>2019-12-08T00:00:00.0000000</embargoDate><copyrightCorrect>true</copyrightCorrect><language>eng</language></document></documents><OutputDurs/></rfc1807> |
spelling |
2019-03-25T12:47:54.3133285 v2 49111 2019-03-05 Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface 77c39404a9a98c6e2283d84815cba053 0000-0003-0174-4151 Karl Hawkins Karl Hawkins true false c71a7a4be7361094d046d312202bce0c 0000-0002-5153-573X Cathy Thornton Cathy Thornton true false 2019-03-05 MEDS Medical devices, such as ventricular assist devices (VADs), introduce both foreign materials and artificial shear stress to the circulatory system. The effects these have on leukocytes and the immune response are not well understood. Understanding how these two elements combine to affect leukocytes may reveal why some patients are susceptible to recurrent device-related infections and provide insight into the development of pump thrombosis. Biomaterials - DLC: diamond-like carbon coated stainless steel; Sap: single-crystal sapphire; and Ti: titanium alloy (Ti6Al4V) were attached to the parallel plates of a rheometer. Whole human blood was left between the two discs for 5 min at +37°C with or without the application of shear stress (0s-1 or 1000s-1). Blood was removed and used for: complete blood cell counts; flow cytometry (leukocyte activation; cell death; microparticle generation; phagocytic ability; and reactive oxygen species (ROS) production); and the production of pro-inflammatory cytokines. L-selectin expression on monocytes was decreased when blood was exposed to the biomaterials both with and without shear. Applying shear stress to blood on a Sap and Ti surface led to activation of neutrophils shown as decreased L-selectin expression. Sap and Ti blunted the LPS-stimulated macrophage migration inhibitory factor (MIF) production, most notably when sheared on Ti.The biomaterials used here have been shown to activate leukocytes in a static environment. The introduction of shear appears to exacerbate this activation. Interestingly, a widely accepted biocompatible material (Ti) utilised in many different types of devices, has the capacity for immune cell activation and inhibition of MIF secretion when combined with shear stress. These findings contribute to our understanding of the contribution of biomaterials and shear stress to recurrent infections and vulnerability to sepsis in some VAD patients as well as pump thrombosis. Journal Article Artificial Organs 0160-564X 1525-1594 Biomaterials, Shear Stress, Human blood, Leukocytes, Flow Cytometry 8 1 2018 2018-01-08 10.1111/aor.13409 COLLEGE NANME Medical School COLLEGE CODE MEDS Swansea University 2019-03-25T12:47:54.3133285 2019-03-05T08:39:32.9438049 Faculty of Medicine, Health and Life Sciences Swansea University Medical School - Medicine Gemma Radley 1 Ina Laura Pieper 2 Bethan R. Thomas 3 Karl Hawkins 0000-0003-0174-4151 4 Cathy Thornton 0000-0002-5153-573X 5 0049111-05032019084007.pdf 20180814_Radley_Cronfa.pdf 2019-03-05T08:40:07.4800000 Output 5850626 application/pdf Accepted Manuscript true 2019-12-08T00:00:00.0000000 true eng |
title |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface |
spellingShingle |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface Karl Hawkins Cathy Thornton |
title_short |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface |
title_full |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface |
title_fullStr |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface |
title_full_unstemmed |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface |
title_sort |
Artificial Shear Stress Effects on Leukocytes at a Biomaterial Interface |
author_id_str_mv |
77c39404a9a98c6e2283d84815cba053 c71a7a4be7361094d046d312202bce0c |
author_id_fullname_str_mv |
77c39404a9a98c6e2283d84815cba053_***_Karl Hawkins c71a7a4be7361094d046d312202bce0c_***_Cathy Thornton |
author |
Karl Hawkins Cathy Thornton |
author2 |
Gemma Radley Ina Laura Pieper Bethan R. Thomas Karl Hawkins Cathy Thornton |
format |
Journal article |
container_title |
Artificial Organs |
publishDate |
2018 |
institution |
Swansea University |
issn |
0160-564X 1525-1594 |
doi_str_mv |
10.1111/aor.13409 |
college_str |
Faculty of Medicine, Health and Life Sciences |
hierarchytype |
|
hierarchy_top_id |
facultyofmedicinehealthandlifesciences |
hierarchy_top_title |
Faculty of Medicine, Health and Life Sciences |
hierarchy_parent_id |
facultyofmedicinehealthandlifesciences |
hierarchy_parent_title |
Faculty of Medicine, Health and Life Sciences |
department_str |
Swansea University Medical School - Medicine{{{_:::_}}}Faculty of Medicine, Health and Life Sciences{{{_:::_}}}Swansea University Medical School - Medicine |
document_store_str |
1 |
active_str |
0 |
description |
Medical devices, such as ventricular assist devices (VADs), introduce both foreign materials and artificial shear stress to the circulatory system. The effects these have on leukocytes and the immune response are not well understood. Understanding how these two elements combine to affect leukocytes may reveal why some patients are susceptible to recurrent device-related infections and provide insight into the development of pump thrombosis. Biomaterials - DLC: diamond-like carbon coated stainless steel; Sap: single-crystal sapphire; and Ti: titanium alloy (Ti6Al4V) were attached to the parallel plates of a rheometer. Whole human blood was left between the two discs for 5 min at +37°C with or without the application of shear stress (0s-1 or 1000s-1). Blood was removed and used for: complete blood cell counts; flow cytometry (leukocyte activation; cell death; microparticle generation; phagocytic ability; and reactive oxygen species (ROS) production); and the production of pro-inflammatory cytokines. L-selectin expression on monocytes was decreased when blood was exposed to the biomaterials both with and without shear. Applying shear stress to blood on a Sap and Ti surface led to activation of neutrophils shown as decreased L-selectin expression. Sap and Ti blunted the LPS-stimulated macrophage migration inhibitory factor (MIF) production, most notably when sheared on Ti.The biomaterials used here have been shown to activate leukocytes in a static environment. The introduction of shear appears to exacerbate this activation. Interestingly, a widely accepted biocompatible material (Ti) utilised in many different types of devices, has the capacity for immune cell activation and inhibition of MIF secretion when combined with shear stress. These findings contribute to our understanding of the contribution of biomaterials and shear stress to recurrent infections and vulnerability to sepsis in some VAD patients as well as pump thrombosis. |
published_date |
2018-01-08T01:54:13Z |
_version_ |
1821368598940090368 |
score |
11.04748 |