No Cover Image

Journal article 987 views

Relaxation time of dilute polymer solutions: A microfluidic approach

Francesco Del Giudice Orcid Logo, Simon J. Haward, Amy Q. Shen

Journal of Rheology, Volume: 61, Issue: 2, Pages: 327 - 337

Swansea University Author: Francesco Del Giudice Orcid Logo

Full text not available from this repository: check for access using links below.

Check full text

DOI (Published version): 10.1122/1.4975933

Abstract

Polymer solutions are considered dilute when polymer chains in a solution do not interact with each other. One important step in the characterization of these systems is the measurement of their longest relaxation times λ. For dilute polymer solutions in low-viscous solvents, this measurement can be...

Full description

Published in: Journal of Rheology
ISSN: 0148-6055 1520-8516
Published: Society of Rheology 2017
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa41012
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: Polymer solutions are considered dilute when polymer chains in a solution do not interact with each other. One important step in the characterization of these systems is the measurement of their longest relaxation times λ. For dilute polymer solutions in low-viscous solvents, this measurement can be very challenging through conventional techniques. Recently, several microfluidic platforms have been successfully employed to measure the rheological properties of weakly viscoelastic solutions. Nevertheless, a comparison between data generated from different microfluidic platforms has not yet been presented. In this work, we measure λ of dilute polymer solutions for concentrations down to a few parts per million, by using two distinct microfluidic platforms with shear and extensional flow configurations. We consider three representative polymer classes: Neutral polymers in near-theta and good solvents, and a biological polyelectrolyte in a good solvent in the presence of salt. Relaxation times in shear flow λshear are measured through the μ-rheometer based on the viscoelastic alignment of particles in a straight microchannel. Relaxation times in extensional flow λext are measured in a microfluidic optimized cross-slot configuration based on the onset of the flow-induced birefringence. A good agreement between experimental measurements from the two platforms is found. Experimental measures are also compared with available theories.
Keywords: Time measurement, Solution polymerization, Polyelectrolytes, Relaxation times, Solvents, Viscosity, Microfluidics, Birefringence, Extensional flows
College: Faculty of Science and Engineering
Issue: 2
Start Page: 327
End Page: 337