Journal article 1546 views 324 downloads
Fractal dimension: A novel clot microstructure biomarker use in ST elevation myocardial infarction patients
Atherosclerosis, Volume: 240, Issue: 2, Pages: 402 - 407
Swansea University Authors: Matthew Lawrence, Ahmed Sabra, Daniel Obaid , Lindsay D´Silva, Karl Hawkins , Rowan Brown , Rhodri Williams , Adrian Evans
-
PDF | Accepted Manuscript
Download (807.5KB)
DOI (Published version): 10.1016/j.atherosclerosis.2015.04.012
Abstract
ObjectivesChanges in clot microstructure are increasingly implicated in the pathology of atherosclerosis although most data are from techniques in the remote laboratory using altered blood. We validate the novel biomarker Gel Point in STEMI patients and assess therapeutic interventions. Gel Point ma...
Published in: | Atherosclerosis |
---|---|
ISSN: | 0021-9150 |
Published: |
Elsevier BV
2015
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa27876 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract: |
ObjectivesChanges in clot microstructure are increasingly implicated in the pathology of atherosclerosis although most data are from techniques in the remote laboratory using altered blood. We validate the novel biomarker Gel Point in STEMI patients and assess therapeutic interventions. Gel Point marks the transition of blood from a visco-elastic liquid to visco-elastic solid and is rapidly measured using unadulterated blood. The Gel Point provides measurements of three parameters to reflect clot microstructure (fractal dimension (df)), real-time clot formation time (TGP) and blood clot strength (elasticity at the Gel Point (G′GP)).MethodsWe prospectively recruited 38 consecutive patients with STEMI undergoing primary percutaneous coronary intervention (pPCI). Venous blood samples were collected on admission, after pPCI and 24 h after admission for assessment of the new biomarkers, standard coagulation tests and scanning electron microscopy (SEM).Resultsdf after pPCI was lower than df on admission (mean 1.631 [SD 0.063] vs 1.751 [0.052], p < 0.000001) whereas df at 24 h was similar to that on admission. G′GP also showed similar trend to df (p < 0.001). TGP was prolonged at after-PCI measurement compared with admission (median 854 s [IQR 581–1801] vs 217 [179–305], p < 0.00001). Changes in the values of df and G′GP were consistent with changes in the SEM images of the mature clot.ConclusionsWe characterise Gel Point derived markers of clot microstructure in patients admitted with emergency arterial thrombosis. This point of care test can potentially be used to assess the efficacy of therapeutic interventions by measuring changes in clot microstructure. |
---|---|
College: |
Faculty of Medicine, Health and Life Sciences |
Issue: |
2 |
Start Page: |
402 |
End Page: |
407 |