Abstract
In the above letter, Chin and Chen proposed an IEEE 1588 clock synchronization method based on dual slave clocks, where they claim that multiple unknown parameters --- i.e., clock offset, clock skew, and master-to-slave delay --- can be estimated with only one-way time transfers using more equations...
| Published in: | IEEE Communications Letters |
|---|---|
| Published: |
2014
|
| Online Access: |
http://arxiv.org/abs/1404.1311 |
| URI: | https://cronfa.swan.ac.uk/Record/cronfa17721 |
| first_indexed |
2014-04-08T01:30:04Z |
|---|---|
| last_indexed |
2018-02-09T04:51:37Z |
| id |
cronfa17721 |
| recordtype |
SURis |
| fullrecord |
<?xml version="1.0"?><rfc1807><datestamp>2014-06-06T19:41:26.5234327</datestamp><bib-version>v2</bib-version><id>17721</id><entry>2014-04-07</entry><title>Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave"</title><swanseaauthors><author><sid>28df2d8e401d3e36b6da4a4124049742</sid><firstname>Joseph</firstname><surname>Kim</surname><name>Joseph Kim</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2014-04-07</date><abstract>In the above letter, Chin and Chen proposed an IEEE 1588 clock synchronization method based on dual slave clocks, where they claim that multiple unknown parameters --- i.e., clock offset, clock skew, and master-to-slave delay --- can be estimated with only one-way time transfers using more equations than usual. This comment investigates Chin and Chen's dual clock scheme with detailed models for a master and dual slave clocks and shows that the formulation of multi-parameter estimation is invalid, which affirms that it is impossible to distinguish the effect of delay from that of clock offset at a slave even with dual slave clocks.</abstract><type>Journal Article</type><journal>IEEE Communications Letters</journal><paginationStart>1</paginationStart><paginationEnd>2</paginationEnd><publisher/><keywords>Clock synchronization, clock offset, clock skew, path delay</keywords><publishedDay>30</publishedDay><publishedMonth>4</publishedMonth><publishedYear>2014</publishedYear><publishedDate>2014-04-30</publishedDate><doi>10.1109/LCOMM.2014.2317738</doi><url>http://arxiv.org/abs/1404.1311</url><notes/><college>COLLEGE NANME</college><CollegeCode>COLLEGE CODE</CollegeCode><institution>Swansea University</institution><apcterm/><lastEdited>2014-06-06T19:41:26.5234327</lastEdited><Created>2014-04-07T11:17:12.4055991</Created><path><level id="1">Faculty of Science and Engineering</level><level id="2">School of Engineering and Applied Sciences - Uncategorised</level></path><authors><author><firstname>Kyeong Soo</firstname><surname>Kim</surname><order>1</order></author><author><firstname>Joseph</firstname><surname>Kim</surname><order>2</order></author></authors><documents/><OutputDurs/></rfc1807> |
| spelling |
2014-06-06T19:41:26.5234327 v2 17721 2014-04-07 Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" 28df2d8e401d3e36b6da4a4124049742 Joseph Kim Joseph Kim true false 2014-04-07 In the above letter, Chin and Chen proposed an IEEE 1588 clock synchronization method based on dual slave clocks, where they claim that multiple unknown parameters --- i.e., clock offset, clock skew, and master-to-slave delay --- can be estimated with only one-way time transfers using more equations than usual. This comment investigates Chin and Chen's dual clock scheme with detailed models for a master and dual slave clocks and shows that the formulation of multi-parameter estimation is invalid, which affirms that it is impossible to distinguish the effect of delay from that of clock offset at a slave even with dual slave clocks. Journal Article IEEE Communications Letters 1 2 Clock synchronization, clock offset, clock skew, path delay 30 4 2014 2014-04-30 10.1109/LCOMM.2014.2317738 http://arxiv.org/abs/1404.1311 COLLEGE NANME COLLEGE CODE Swansea University 2014-06-06T19:41:26.5234327 2014-04-07T11:17:12.4055991 Faculty of Science and Engineering School of Engineering and Applied Sciences - Uncategorised Kyeong Soo Kim 1 Joseph Kim 2 |
| title |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" |
| spellingShingle |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" Joseph Kim |
| title_short |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" |
| title_full |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" |
| title_fullStr |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" |
| title_full_unstemmed |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" |
| title_sort |
Comments on "IEEE 1588 Clock Synchronization using Dual Slave Clocks in a Slave" |
| author_id_str_mv |
28df2d8e401d3e36b6da4a4124049742 |
| author_id_fullname_str_mv |
28df2d8e401d3e36b6da4a4124049742_***_Joseph Kim |
| author |
Joseph Kim |
| author2 |
Kyeong Soo Kim Joseph Kim |
| format |
Journal article |
| container_title |
IEEE Communications Letters |
| container_start_page |
1 |
| publishDate |
2014 |
| institution |
Swansea University |
| doi_str_mv |
10.1109/LCOMM.2014.2317738 |
| college_str |
Faculty of Science and Engineering |
| hierarchytype |
|
| hierarchy_top_id |
facultyofscienceandengineering |
| hierarchy_top_title |
Faculty of Science and Engineering |
| hierarchy_parent_id |
facultyofscienceandengineering |
| hierarchy_parent_title |
Faculty of Science and Engineering |
| department_str |
School of Engineering and Applied Sciences - Uncategorised{{{_:::_}}}Faculty of Science and Engineering{{{_:::_}}}School of Engineering and Applied Sciences - Uncategorised |
| url |
http://arxiv.org/abs/1404.1311 |
| document_store_str |
0 |
| active_str |
0 |
| description |
In the above letter, Chin and Chen proposed an IEEE 1588 clock synchronization method based on dual slave clocks, where they claim that multiple unknown parameters --- i.e., clock offset, clock skew, and master-to-slave delay --- can be estimated with only one-way time transfers using more equations than usual. This comment investigates Chin and Chen's dual clock scheme with detailed models for a master and dual slave clocks and shows that the formulation of multi-parameter estimation is invalid, which affirms that it is impossible to distinguish the effect of delay from that of clock offset at a slave even with dual slave clocks. |
| published_date |
2014-04-30T04:57:00Z |
| _version_ |
1851277097580888064 |
| score |
11.090362 |