No Cover Image

Journal article 1336 views

Load current observer based feed-forward DC bus voltage control for active rectifiers

Z. Zhou, C. Wang, Y. Liu, P.M. Holland, P. Igic, Petar Igic Orcid Logo, Zhongfu Zhou Orcid Logo

Electric Power Systems Research, Volume: 84, Issue: 1, Pages: 165 - 173

Swansea University Authors: Petar Igic Orcid Logo, Zhongfu Zhou Orcid Logo

Full text not available from this repository: check for access using links below.

Abstract

In this paper, load current observer based feedforward control of DC bus voltage for a three-phase active rectifier is presented. The paper focuses on: (1) design of conventional proportional-integral (PI) current controller with fastest possible response, (2) the digital current control loop time-d...

Full description

Published in: Electric Power Systems Research
ISSN: 0378-7796
Published: 2012
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa12570
Tags: Add Tag
No Tags, Be the first to tag this record!
first_indexed 2013-07-23T12:08:15Z
last_indexed 2018-02-09T04:43:05Z
id cronfa12570
recordtype SURis
fullrecord <?xml version="1.0"?><rfc1807><datestamp>2017-10-11T11:01:51.4527352</datestamp><bib-version>v2</bib-version><id>12570</id><entry>2013-01-21</entry><title>Load current observer based feed-forward DC bus voltage control for active rectifiers</title><swanseaauthors><author><sid>e085acc259a367abc89338346a150186</sid><ORCID>0000-0001-8150-8815</ORCID><firstname>Petar</firstname><surname>Igic</surname><name>Petar Igic</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>614fc57cde2ee383718d4f4c462b5fba</sid><ORCID>0000-0002-0843-7253</ORCID><firstname>Zhongfu</firstname><surname>Zhou</surname><name>Zhongfu Zhou</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2013-01-21</date><deptcode>EEN</deptcode><abstract>In this paper, load current observer based feedforward control of DC bus voltage for a three-phase active rectifier is presented. The paper focuses on: (1) design of conventional proportional-integral (PI) current controller with fastest possible response, (2) the digital current control loop time-delay compensation, (3) design of dc-link-load current observer for identifying the dc load current without using actual current sensors and (4) the feedforward control of dc bus voltage based on the designed current controller and dc link load current observer. A prototype is developed based on the proposed control scheme and expected results have been achieved.</abstract><type>Journal Article</type><journal>Electric Power Systems Research</journal><volume>84</volume><journalNumber>1</journalNumber><paginationStart>165</paginationStart><paginationEnd>173</paginationEnd><publisher/><issnPrint>0378-7796</issnPrint><keywords>Active rectifier; Feed-forward control; Current controller; Observer; Time-delay compensation</keywords><publishedDay>31</publishedDay><publishedMonth>12</publishedMonth><publishedYear>2012</publishedYear><publishedDate>2012-12-31</publishedDate><doi>10.1016/j.epsr.2011.11.008</doi><url/><notes>A load current observer based feed forward control scheme for three-phase voltage source pulse width modulation (PWM) active rectifiers is developed. This provides a control solution for fast dc bus voltage control without measuring dc link load current and results in a reduction of cost required for the current sensors. In additional to the fast current control technique developed, a method of estimating dc link capacitance is also developed and verified using simulation program. Test results were illustrated at the end of the paper. The journal's impact factor in 2012 is: 1.481</notes><college>COLLEGE NANME</college><department>Engineering</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>EEN</DepartmentCode><institution>Swansea University</institution><apcterm/><lastEdited>2017-10-11T11:01:51.4527352</lastEdited><Created>2013-01-21T06:01:12.0000000</Created><path><level id="1">Faculty of Science and Engineering</level><level id="2">School of Engineering and Applied Sciences - Uncategorised</level></path><authors><author><firstname>Z.</firstname><surname>Zhou</surname><order>1</order></author><author><firstname>C.</firstname><surname>Wang</surname><order>2</order></author><author><firstname>Y.</firstname><surname>Liu</surname><order>3</order></author><author><firstname>P.M.</firstname><surname>Holland</surname><order>4</order></author><author><firstname>P.</firstname><surname>Igic</surname><order>5</order></author><author><firstname>Petar</firstname><surname>Igic</surname><orcid>0000-0001-8150-8815</orcid><order>6</order></author><author><firstname>Zhongfu</firstname><surname>Zhou</surname><orcid>0000-0002-0843-7253</orcid><order>7</order></author></authors><documents/><OutputDurs/></rfc1807>
spelling 2017-10-11T11:01:51.4527352 v2 12570 2013-01-21 Load current observer based feed-forward DC bus voltage control for active rectifiers e085acc259a367abc89338346a150186 0000-0001-8150-8815 Petar Igic Petar Igic true false 614fc57cde2ee383718d4f4c462b5fba 0000-0002-0843-7253 Zhongfu Zhou Zhongfu Zhou true false 2013-01-21 EEN In this paper, load current observer based feedforward control of DC bus voltage for a three-phase active rectifier is presented. The paper focuses on: (1) design of conventional proportional-integral (PI) current controller with fastest possible response, (2) the digital current control loop time-delay compensation, (3) design of dc-link-load current observer for identifying the dc load current without using actual current sensors and (4) the feedforward control of dc bus voltage based on the designed current controller and dc link load current observer. A prototype is developed based on the proposed control scheme and expected results have been achieved. Journal Article Electric Power Systems Research 84 1 165 173 0378-7796 Active rectifier; Feed-forward control; Current controller; Observer; Time-delay compensation 31 12 2012 2012-12-31 10.1016/j.epsr.2011.11.008 A load current observer based feed forward control scheme for three-phase voltage source pulse width modulation (PWM) active rectifiers is developed. This provides a control solution for fast dc bus voltage control without measuring dc link load current and results in a reduction of cost required for the current sensors. In additional to the fast current control technique developed, a method of estimating dc link capacitance is also developed and verified using simulation program. Test results were illustrated at the end of the paper. The journal's impact factor in 2012 is: 1.481 COLLEGE NANME Engineering COLLEGE CODE EEN Swansea University 2017-10-11T11:01:51.4527352 2013-01-21T06:01:12.0000000 Faculty of Science and Engineering School of Engineering and Applied Sciences - Uncategorised Z. Zhou 1 C. Wang 2 Y. Liu 3 P.M. Holland 4 P. Igic 5 Petar Igic 0000-0001-8150-8815 6 Zhongfu Zhou 0000-0002-0843-7253 7
title Load current observer based feed-forward DC bus voltage control for active rectifiers
spellingShingle Load current observer based feed-forward DC bus voltage control for active rectifiers
Petar Igic
Zhongfu Zhou
title_short Load current observer based feed-forward DC bus voltage control for active rectifiers
title_full Load current observer based feed-forward DC bus voltage control for active rectifiers
title_fullStr Load current observer based feed-forward DC bus voltage control for active rectifiers
title_full_unstemmed Load current observer based feed-forward DC bus voltage control for active rectifiers
title_sort Load current observer based feed-forward DC bus voltage control for active rectifiers
author_id_str_mv e085acc259a367abc89338346a150186
614fc57cde2ee383718d4f4c462b5fba
author_id_fullname_str_mv e085acc259a367abc89338346a150186_***_Petar Igic
614fc57cde2ee383718d4f4c462b5fba_***_Zhongfu Zhou
author Petar Igic
Zhongfu Zhou
author2 Z. Zhou
C. Wang
Y. Liu
P.M. Holland
P. Igic
Petar Igic
Zhongfu Zhou
format Journal article
container_title Electric Power Systems Research
container_volume 84
container_issue 1
container_start_page 165
publishDate 2012
institution Swansea University
issn 0378-7796
doi_str_mv 10.1016/j.epsr.2011.11.008
college_str Faculty of Science and Engineering
hierarchytype
hierarchy_top_id facultyofscienceandengineering
hierarchy_top_title Faculty of Science and Engineering
hierarchy_parent_id facultyofscienceandengineering
hierarchy_parent_title Faculty of Science and Engineering
department_str School of Engineering and Applied Sciences - Uncategorised{{{_:::_}}}Faculty of Science and Engineering{{{_:::_}}}School of Engineering and Applied Sciences - Uncategorised
document_store_str 0
active_str 0
description In this paper, load current observer based feedforward control of DC bus voltage for a three-phase active rectifier is presented. The paper focuses on: (1) design of conventional proportional-integral (PI) current controller with fastest possible response, (2) the digital current control loop time-delay compensation, (3) design of dc-link-load current observer for identifying the dc load current without using actual current sensors and (4) the feedforward control of dc bus voltage based on the designed current controller and dc link load current observer. A prototype is developed based on the proposed control scheme and expected results have been achieved.
published_date 2012-12-31T03:14:28Z
_version_ 1763750202043269120
score 11.036553